Air Conditioning Not Cooling: Causes, Checks and Repair Costs

The fan is running, the remote says 18°C, and the room is still warm. Here are the causes in the order engineers find them, what is safe to check yourself, and what each repair costs in 2026.

Get air con repair quotes

The six causes, in the order engineers find them

Air conditioning stops cooling for surprisingly few reasons. Many "not cooling" call-outs are resolved by airflow or settings; the rest split between refrigerant, electrical parts and, rarely, the compressor.

1. Dirty filters or a blocked coil

The most common cause by a distance. Once the mesh filters clog, too little air passes over the cold coil, the unit cannot shed heat and may begin to ice up. Lift the front panel, slide the filters out, wash in lukewarm water, dry and refit. In a home running its air conditioning hard through a hot spell, once a month is about right; a wall unit in a dusty room or with pets around clogs faster than that. If it is over a year since a service, the coil behind the filters may be furred up too, and a blocked condensate drain can start the unit cutting out — both need a proper clean by an engineer rather than a rinse at the sink.

2. Wrong mode, set-point or timer

Check the remote is in cool (snowflake) rather than fan, dry or auto, that the set temperature is below room temperature, that eco or sleep mode is not capping output and that a timer has not put the unit into standby. Flat remote batteries cause more "breakdowns" than anyone admits. On a multi-split every head must be in the same mode — one in heat blocks the others from cooling.

3. Frozen evaporator coil

Weak airflow plus frost on the pipes or ice behind the filters means the coil has frozen. Switch off and let it thaw for a couple of hours — expect dripping. Restricted airflow is the benign cause; if it freezes again with clean filters, the charge is low and you are at cause four.

4. Low refrigerant — which always means a leak

Split systems are sealed and do not "use up" gas, so a low charge means refrigerant has escaped through a flare joint, corroded coil or damaged pipe. Symptoms: cooling that has faded over weeks, hissing, ice on the thin pipe, sometimes an error code. The usual escape points are the flare joints where the pipework meets each unit, a corroded outdoor coil, or pipe runs that have chafed against a wall. Most modern splits are charged with R32, which is mildly flammable (an A2L refrigerant), so a DIY top-up is not only illegal without certification — done wrong it is genuinely unsafe. Only an F-Gas certified engineer may trace and fix the leak, pressure-test and re-gas; our re-gas cost guide explains why a top-up alone is not an option.

5. Failed capacitor or fan motor

Go outside. If the outdoor fan is not turning, or the unit hums and clicks but never starts, a run capacitor or fan motor has usually failed — routine, same-day repairs where the bill is mostly the call-out.

6. Compressor

Least common, most serious. A compressor that will not start, trips the breaker or knocks loudly is a stop-and-think moment: on a unit over ten years old, part and labour often exceed half the cost of a new system. See repair or replace? first.

What you can check yourself — and what needs an F-Gas engineer

Anything behind the filter panel or inside the outdoor casing involves mains voltage, a pressurised refrigerant circuit or both. Clean, look and reset — never open, connect or top up.

CheckSafe to do yourself?Why
Clean or replace indoor filtersYesNo tools, no electrics — just the front panel and a sink
Clear leaves, covers and stored items from the outdoor unitYesThe outdoor coil needs free airflow on all sides; keep 30 cm clear
Switch off at the isolator, wait ten minutes, restartYesClears many protection lock-outs and some error codes
Open the outdoor unit, test capacitors or wiringNoCapacitors hold a charge after power is off; live terminals inside
Add refrigerant, open valves or fit gaugesNo — illegal without F-Gas certificationVenting refrigerant is an offence and a top-up without a leak repair is wasted

If a check on the left fixes it, book a service anyway — neglect brings the fault back.

Typical repair cost by cause (2026)

Call-outs typically run £80–£150 and include diagnosis plus minor work; parts are extra and refrigerant work is priced separately. Ranges are UK baselines — get quotes for your unit. Many engineers will credit the diagnostic call-out against the bill if you go ahead with the repair on the day, so it is worth asking when you book.

CauseTypical fixTypical cost
Dirty filters / blocked coilDIY filter wash, or engineer coil clean as part of a service£0 DIY · £75–£150 service
Frozen evaporator (airflow cause)Thaw, clean, check fan — call-out only£80–£150
Low refrigerant (leak)Find and fix leak, pressure test, re-gas£100–£300 re-gas + leak repair
Failed capacitor or outdoor fan motorReplace on the day — call-out plus the part£80–£150 + part
CompressorQuote basis — compare with a new unitOften uneconomic vs £1,500–£3,000 new

Baselines: call-out £80–£150; re-gas £100–£300; single split installed £1,500–£3,000. Full breakdown in air conditioning repair costs.

When "not cooling" means it is time for a new unit

Three signals tip the balance. Age: past 10–15 years units lose efficiency and parts get scarce. Refrigerant: R22 cannot legally be re-gassed and R410A is being phased down under F-Gas quotas; today's units run on R32. The 50% rule: if the repair quote exceeds half the price of a new system — £1,500–£3,000 for a single wall-mounted split — buy a new, warrantied unit. Daikin and Mitsubishi Electric carry 5–7 year warranties through accredited installers. Filter, capacitor or fan: repair. Compressor, or a leak on an old R410A system: read repair or replace? and get both quotes.

Sources & methodology

  • Fault order reflects the diagnostic sequence in manufacturer service manuals (Daikin, Mitsubishi Electric, Fujitsu, Panasonic, LG, Samsung).
  • Refrigerant handling: GB F-Gas Regulation (retained Regulation (EU) 517/2014) — only certified persons may recover, charge or check for leaks; venting is an offence.
  • Price baselines are 2026 UK figures used across this site: call-out £80–£150, re-gas £100–£300, service £75–£150, single split installed £1,500–£3,000.

FAQs

In order of likelihood: clogged filters, the wrong mode or set-point, a frozen indoor coil, low refrigerant from a leak, a failed capacitor or fan motor outdoors, and finally a worn compressor. Check the first two yourself before booking an engineer.
No. Only an F-Gas certified engineer may handle refrigerant, and a low charge always means a leak. A re-gas costs around £100–£300, but the leak must be found and repaired first — topping up alone is illegal and pointless because it will escape again.
Budget for a call-out of £80–£150 including diagnosis and minor fixes. Parts are extra; a leak repair plus re-gas typically lands in the £100–£300 range. A failed compressor is the exception and often costs more than half the price of a new unit.
Ice forms when the coil runs colder than it should — because airflow is restricted (dirty filters, blocked coil, fan fault) or the refrigerant charge is low. Switch off, let it thaw fully, clean the filters and try again. If it re-freezes, it is almost certainly a leak and needs an engineer.
If the unit is 10–15 years old, runs on obsolete R22, or needs a compressor, a repair quote can approach the £1,500–£3,000 cost of a new single split. As a rule of thumb, repairs over half the price of a new unit rarely make sense — see our repair-or-replace guide.
Yes, and it is money wasted. A unit that runs but does not cool still drives its fan and, unless the compressor itself has failed, keeps drawing close to full power for no result. At the Ofgem cap rate — around 26p per kWh, 26.11p until 30 September 2026 then 26.32p from 1 October — a 2.5kW split working flat out costs roughly 18–23p an hour, so leaving a faulty unit on all day adds up quickly. Switch it off until it is fixed. Our running costs guide has the full picture.
A correctly sized split should take the edge off within 10–15 minutes and reach your set temperature in half an hour or so, quicker in a small, well-insulated room. If an hour passes with no real change on a warm day, something is wrong — start with the filters and the mode, then look at airflow and refrigerant. A unit that is simply too small for the room will run constantly and never quite get there, which is a sizing problem rather than a fault.
This one comes up a lot in a heatwave. If the unit keeps a room comfortable first thing but loses ground once it is in the high 20s or low 30s outside, it is being asked for more cooling than it can deliver under load. The usual reasons are a coil or filters that need cleaning, which quietly cuts capacity; a slightly low refrigerant charge that only shows up when the unit is working hard; or a unit that was undersized for the room in the first place. Clean the filters first, and if the pattern continues get an engineer to check the charge and confirm the sizing.

Still warm? Get repair quotes from vetted engineers

Tell us the symptoms and your postcode and we match you with vetted, F-Gas certified repair engineers near you. Free, no obligation — compare quotes and decide.